Skip to content
OctoServer 4U chassis from above with the lid half open

Engineering

One chassis design, engineered for sustained GPU load.

Backplanes, cooling, power and management shared across the range, so every platform runs its GPUs under sustained load without thermal issues.

Backplanes and link width

Every GPU slot on a defined link.

Slot count and link width are fixed by the backplane. Most deployments keep eight GPUs or fewer, which leaves PCIe lanes for NVMe storage and fast network cards.

4U-E12G-ROME12× dual-slot GPUs at PCIe 4.0 x8, or 6× 3.5-slot GPUs at PCIe 4.0 x16
4U-E10G-ROMEX29× PCIe 4.0 x16 slots for dual-slot GPUs (FH/FL)
4U-E10G-GENOAX29× PCIe 5.0 x16 slots for dual-slot GPUs (FH/FL)
Ten GPUsOnly with the upgradeable PCIe switch GPU backplane, or 8 GPUs at x16 plus 2 at x8 (ROMEX2 and GENOAX2)

Thermal design

High static pressure, push-pull airflow.

Dense GPU layouts need uniform airflow across every card. Counter-rotating dual-motor central fans (120×76 mm) and rear high static pressure fans form a push-pull array.

  • 3× 7200 RPM counter-rotating central fans
  • 3× 7200 RPM high static pressure fans
  • Sized for 450 W-class GPUs such as the RTX 4090
Counter-rotating dual-motor fan module

Power delivery

Redundant Platinum supplies on copper.

CRPS supplies in N+1, distributed over heavy copper PCBs.

4U-E12G-ROME4800 W: 2+1 redundant 1600 W 80 PLUS Platinum CRPS
4U-E10G-ROMEX2 and GENOAX26400 W: 3+1 redundant 1600 W 80 PLUS Platinum CRPS
Upgrade path3+1 redundant 2000 W 80 PLUS Titanium
DistributionThick copper 4 oz and 8 oz PCBs instead of cable looms

Modular expansion

Storage modules for the dual-socket platforms.

Up to 12 PCIe slots on the ROME, plus 1 OCP 3.0 x16 slot and 1 PCIe 4.0 x8 slot.

PCIe 4.0 switch with eight 2.5-inch U.2 NVMe bays

PCIe 4.0 switch + 8× 2.5" U.2 NVMe

Option 1 for ROMEX2 and GENOAX2: eight hot-swap U.2 NVMe drives behind a PCIe 4.0 switch.

Eight hot-swap 3.5-inch drive bays

8× hot-swap 3.5" bays

Optional bulk storage module for datasets and archives.

Remote management

IPMI 2.0 with iKVM and virtual media.

ASPEED AST2500 on ROME and ROMEX2, AST2600 on GENOAX2, with an HTML5 console in the browser.

Browser-based server management console overview

Run under load before it ships.

Every system is powered up, checked and run under load in Tallinn before packing. A full-load stress test ran nine RTX 4090 cards in one 4U-E10G-ROMEX2.